Add your idea or search for answers in existing topics. The most popular ideas will be implemented faster!
We have moved our support service to a new technical support system. Since 17.01.2022, we have disabled the ability to create appeals through the userecho personal account. Now all requests are processed via mail to support@iridi.com .
Thank you for your understanding and have a nice day.
Geen vergelijkbare onderwerpen gevonden.
0
Beantwoord
Show a menu - and hide with a time-out timer if not pressed for 10 seconds.
even 10 jaar geleden
in GUI Editor
•
bijgewerkt door Ekaterina (head of support) 10 jaar geleden •
3
I have a Samsung "Smart TV", and have issues trying to control the "smart functionality".
The TV has a button called "SmartHUB". It is basically a menu that pops in to the screen from the bottom. with the "smart" functionallity the TV offers.
I wonder if I some how can "mimic" the same kind of functionality on the remote.
Displaying the pop-up menu when pressing the "SMartHUB" button.
If (for 10 seconds) if nothing else is pressed. The pop-up menu disapears down again.
Within those 10 seconds I need to change the IR Codes for my navigation keys (up, down, left, right, enter/OK) to control the Samsung TV and not the default device (a decoder). This is best done with an overlaying page I guess, but I am not sure how to best solve it, so please guide me.
Tried to do a mock-up here to illustrate but you should really see the Samsung SmartHUB behaviour to see what I mean. See this video:
at 1:12 + where the menu is viewed.
Please help me :)
Menu_with_timeout.irpz
The TV has a button called "SmartHUB". It is basically a menu that pops in to the screen from the bottom. with the "smart" functionallity the TV offers.
I wonder if I some how can "mimic" the same kind of functionality on the remote.
Displaying the pop-up menu when pressing the "SMartHUB" button.
If (for 10 seconds) if nothing else is pressed. The pop-up menu disapears down again.
Within those 10 seconds I need to change the IR Codes for my navigation keys (up, down, left, right, enter/OK) to control the Samsung TV and not the default device (a decoder). This is best done with an overlaying page I guess, but I am not sure how to best solve it, so please guide me.
Tried to do a mock-up here to illustrate but you should really see the Samsung SmartHUB behaviour to see what I mean. See this video:
at 1:12 + where the menu is viewed.
Please help me :)
Menu_with_timeout.irpz
0
Beantwoord
Cbus shutter control
Damian Hartin 10 jaar geleden
in Products / C-Bus (Clipsal)
•
bijgewerkt door Olga (expert) 10 jaar geleden •
13
Hi,
Is anyone able to give some pointers as to how I work with a CBus shutter control. Not sure of the button type/config I need.
Keeping the default settings from the CBus Cgate driver (as lighting app and immediate ramp) with a trigger button lets move the blinds in one direction only.
Have tried cloning the command and changing to on/off but wasn't able to get it working.
Thanks,
Damian
Is anyone able to give some pointers as to how I work with a CBus shutter control. Not sure of the button type/config I need.
Keeping the default settings from the CBus Cgate driver (as lighting app and immediate ramp) with a trigger button lets move the blinds in one direction only.
Have tried cloning the command and changing to on/off but wasn't able to get it working.
Thanks,
Damian
Antwoord
Olga (expert)
10 jaar geleden
Dear Damian,
Please see the example of using the button here: CBusTestBed_iPhone (button).irpz
Commands are assigned to the button using Send Number. Then write a number depending on the button function (Up = 255).
If you want to control from 1 button, then you have to use scripts. Please describe in details what you want to get from the button (for example, what will happen to the button if you click on the it in iRidium - your curtains go up and then you strop them using the wall panel, not the interface. In what sequence should the commands be sent when clicking Up/Down/Stop? etc.)
Sincerely yours,
Olga Ermakova
iRidium mobile Team
Please see the example of using the button here: CBusTestBed_iPhone (button).irpz
Commands are assigned to the button using Send Number. Then write a number depending on the button function (Up = 255).
If you want to control from 1 button, then you have to use scripts. Please describe in details what you want to get from the button (for example, what will happen to the button if you click on the it in iRidium - your curtains go up and then you strop them using the wall panel, not the interface. In what sequence should the commands be sent when clicking Up/Down/Stop? etc.)
Sincerely yours,
Olga Ermakova
iRidium mobile Team
0
Beantwoord
MyHome system problems
Hi everyone,
We are an unique intergator of MyHome system (Ateror-Legrand_France & Axolute-Bticino_Italy) in VietNam. I saw the description about license for your product but it's not clear about my system. Could you show me the license type i should buy for using I2control for all my projects we do (always about 20-50 project/ 1 year with mainly project type is villa, penthouse and luxury apartment). The subsystems we do including :
+ Lighting and home automation
+ Safety and Burlar Alarm system
+ Sound Distribution system
+ IP camera with many different brands
+ VRV or Split air conditioning system :
- With VRV system, now i see you just have coolmaster 1000D for Daikin VRV, How about another brand such air Panasonic, LG, Samsung,...? and with the coolMaster 1000D unit, MyHome system can be easy to connect, control and monitor the Daikin VRV system? )
I hope you can help me with two questions about license and Air conditioning system which i mention above. Thank you so much !
We are an unique intergator of MyHome system (Ateror-Legrand_France & Axolute-Bticino_Italy) in VietNam. I saw the description about license for your product but it's not clear about my system. Could you show me the license type i should buy for using I2control for all my projects we do (always about 20-50 project/ 1 year with mainly project type is villa, penthouse and luxury apartment). The subsystems we do including :
+ Lighting and home automation
+ Safety and Burlar Alarm system
+ Sound Distribution system
+ IP camera with many different brands
+ VRV or Split air conditioning system :
- With VRV system, now i see you just have coolmaster 1000D for Daikin VRV, How about another brand such air Panasonic, LG, Samsung,...? and with the coolMaster 1000D unit, MyHome system can be easy to connect, control and monitor the Daikin VRV system? )
- With Split air conditioning, do you have any solution?
I hope you can help me with two questions about license and Air conditioning system which i mention above. Thank you so much !
Antwoord
Olga (expert)
10 jaar geleden
Dear Sir,
There are only Device licenses for MyHome. If you need to control MyHome and AV drivers you have to use Device "Pro".
Conditioners can be controlled via IR with the help of Global Cache - you can see the database of IR commands (GC Cloud) in the editor.
You can see our ready solutions on our web site.
Sincerely yours,
Olga Ermakova
iRidium mobile Team
There are only Device licenses for MyHome. If you need to control MyHome and AV drivers you have to use Device "Pro".
Conditioners can be controlled via IR with the help of Global Cache - you can see the database of IR commands (GC Cloud) in the editor.
You can see our ready solutions on our web site.
Sincerely yours,
Olga Ermakova
iRidium mobile Team
0
Voltooid
HDL Watchdog
Ekaterina (head of support) 10 jaar geleden
in Products / HDL-BUS Pro
•
bijgewerkt door AlexDr 8 jaar geleden •
7
This simple script make you able to see if the communication with HDL bus stopped.
In case of UDP broadcast connections it is not possible to see the online status of HDL IP module, so you have to look at the traffic from HDL, and if it is stopped for awhile you can show "Offline message".
See the example attached.
You can choose a time without traffic indicates the offline. It is 10 sec by default.
!HDL Online indicator.irpz
In case of UDP broadcast connections it is not possible to see the online status of HDL IP module, so you have to look at the traffic from HDL, and if it is stopped for awhile you can show "Offline message".
See the example attached.
You can choose a time without traffic indicates the offline. It is 10 sec by default.
!HDL Online indicator.irpz
0
Waiting for user's reply
global event when touching any object on the screen
Hi,
It would be nice if we had an event which is fired when someone touches the screen on an object, regardless to the object.
This way we could create things like automatic logout after x minutes or custom screensavers (with user definable timeouts).
A token which holds the passed time after the last press, is another option to create this functionallity.
Thanks, Benno
It would be nice if we had an event which is fired when someone touches the screen on an object, regardless to the object.
This way we could create things like automatic logout after x minutes or custom screensavers (with user definable timeouts).
A token which holds the passed time after the last press, is another option to create this functionallity.
Thanks, Benno
0
Beantwoord
Импорт драйвера KNX или переменных в существующий драйвер KNX
Владимир Нестеров 9 jaar geleden
in Products / KNX
•
bijgewerkt door Ekaterina (head of support) 9 jaar geleden •
1
Добрый день.
Хотелось бы понять существует ли форма, аналогичная форме файла xls для ModbusTCP, чтобы импортировать переменные KNX (commands, feedback).
Переменных большое число, делать проект в ETS не удобно, т.к. очень большое число переменных и проекта не будет.
Хотелось бы сделать файл и импортировать его в либо как дополнительный драевер, либо как добавление переменных в существующий драйвер.
Хотелось бы понять существует ли форма, аналогичная форме файла xls для ModbusTCP, чтобы импортировать переменные KNX (commands, feedback).
Переменных большое число, делать проект в ETS не удобно, т.к. очень большое число переменных и проекта не будет.
Хотелось бы сделать файл и импортировать его в либо как дополнительный драевер, либо как добавление переменных в существующий драйвер.
0
Voltooid
Script for Arrowhead Elite-S Security Board
Jackie Roos 11 jaar geleden
in JS modules
•
bijgewerkt door Ekaterina (head of support) 10 jaar geleden •
0
Hello
Attached is a sample project with javascript, and document on how to use the script for Arrowhead Elite-S Security
Feel free to contact me directly if you have any questions about the script :)
JAMware Arrowhead Elite-S Sample 6.0.irpz
FYI
To use a Global Cache IP2SL instead of iRidium Gate as in the documentation, enter the IP address of the IP2SL, and the port as 4999 (a global cache driver is not required for serial)
The Elite-S is also called "Avolution"
Attached is a sample project with javascript, and document on how to use the script for Arrowhead Elite-S Security
Feel free to contact me directly if you have any questions about the script :)
JAMware Arrowhead Elite-S Sample 6.0.irpz
FYI
To use a Global Cache IP2SL instead of iRidium Gate as in the documentation, enter the IP address of the IP2SL, and the port as 4999 (a global cache driver is not required for serial)
The Elite-S is also called "Avolution"
0
Waiting for user's reply
Moving files to \\Documents since version 2.2
Theo Derks - NL (distributor) 10 jaar geleden
in General
•
bijgewerkt door Oksana (expert) 10 jaar geleden •
2
Hi,
When installing version 2.2, all user-related files are moved to the Documents folder from the user.
In a normal environment (stand-alone PC or laptop) this is not a problem.
But in big office-environments, where all Documents-folders are shares on the File-server, users can have problems; because there is set a quota on the number of files and the amount of megabytes.
Is it possible to let installer choose where the location of these files is stored?
We already got 3 or 4 problems (calls) about this issue.
Thanks
Theo
When installing version 2.2, all user-related files are moved to the Documents folder from the user.
In a normal environment (stand-alone PC or laptop) this is not a problem.
But in big office-environments, where all Documents-folders are shares on the File-server, users can have problems; because there is set a quota on the number of files and the amount of megabytes.
Is it possible to let installer choose where the location of these files is stored?
We already got 3 or 4 problems (calls) about this issue.
Thanks
Theo
0
Under review
RGB LED strip lighting
Emery Anderson 9 jaar geleden
in General
•
bijgewerkt door Ekaterina (head of support) 9 jaar geleden •
1
Hi All,
I'm looking to add RGB LED strip lighting to an existing project and wanted to ask the forum for ideas / experience with this task. I'm considering using MODBUS via Arduino or Integ JNIOR 412 microcontroller to issue commands and receive feedack via TCP. Would appreciate any suggestions or tips from the group.
Here's a link to the LED strip I'd like to use...
http://www.adafruit.com/products/285
I'm looking to add RGB LED strip lighting to an existing project and wanted to ask the forum for ideas / experience with this task. I'm considering using MODBUS via Arduino or Integ JNIOR 412 microcontroller to issue commands and receive feedack via TCP. Would appreciate any suggestions or tips from the group.
Here's a link to the LED strip I'd like to use...
http://www.adafruit.com/products/285
0
Voltooid
control air conditioner with global cache and coolmaster 1000D
when I try to control the AC unit with iTest software it works fine, but when you try to control using Iridium software, it does not work?.this is my project, use on/off air DAIKIN test coolmaster.irpz
Customer support service by UserEcho