Hello friends, can you help me with the Token ring programming? Thank you
Hello friends, can you help me with the Token ring programming? Thank you

radiora2 lutron drivers
has anyone used the lutron radiora2 system with iridium?and if you have drivers for that system to work with iridium?

iRidium Server check if Panel is online/offline
Is there any chance to iridium Server checks if a panel is conected or not conected?
I want to show on another panel a list of panels online and offline.

Import .csv or .xml for a Bacnet Project on iRidium Server
Hi,
I have a big project with 7 Bacnet Controllers on iridium Server. Each controller is connected to lights, shades and HVAC thermostats. I´ll have a lot of work to create each Command and Feedback. I want to know if there is another choice to create commands and feedbacks on Excel (csv or xml) file than import to iridium.

Show messages time depending
I want to show on panel messages like Good Morning, Good Afternoon and Good Evening depending on time of the day.
I think about to use SetInteval and a function to check how time it is. But I don´t know if it is a good choice.
Can you help me?

Overview Tcp/Udp communications
For a project we need to specify all network ports (TCP/UDP) used by Iridium.
For the server I presume it's only
- http : TCP port 8888
- iridium client 30464 (TCP?)
- Specific driver ports according to the protocols used
for a client connected to a server I assume it's only 30464?
for a client connected directly to end devices it are only the driver specific ports?
for updates to both client and server I guess 433 is used?
Are there any others I forgot? Or is there any documentation on this available?

lutron
Lutron blinds and Shades control
Does anybody has the experience working with Lutron and Controlling by iridium pro?

RTSP Cameras with H265 codecs.
Hi Iridium Team.
I know that Iridium Pro and Iridium Lite can monitor cameras via RSTP with H264 codec. However, I don´t know if both apps support H265 codecs.

Trigger a script from a button press
I am working on a small project where by depending on the value of a server tag/feedback, when a button is pressed it will show a particular popup.
IR.AddListener(IR.EVENT_TAG_CHANGE , IR.GetDevice("F10A-SERVER-01"), function(name,value) { IR.Log("Name = " + name + ", Value = " + value); //For Debug Only if(name == "LAB1-SIM" && value == 1) { IR.ShowPopup("LabLink_Receive_Lab1"); } else if(name == "LAB1-SIM" && value == 0) { IR.ShowPopup("LabLink_NoAccess"); } }); };
In this example, there is a tag on my server called 'LAB1-SIM.' When a particular button is pressed (lets call it 'load' for now) it should load either the 'LabLink_Receive_Lab1' or 'LabLink_NoAccess' popup depending on the value of the tag (0 or 1).
The trouble I have is tying this script to a button press. The script should only be executed when the button is pressed, not at project startup or if the tag value changes. Any help would be greatly appreciated!

Can I hide the name and dotted bounding box in the studio editorso that I can edit very small buttons?
In the GUI editor, the name of a button is always show in the top left, can I switch this off?
Also can I switch off the dotted bounding box?