Welcome!

On this forum you can discuss iRidium with other users.

iRidium consist of 2 main components - i3 pro app and iRidium Server. Please post here your questions, ideas or errors you find.

Please send your questions to support team as a private messages.


Please subscribe to the Change Log to know our news

We have moved our support service to a new technical support system. Since 17.01.2022, we have disabled the ability to create appeals through the userecho personal account. Now all requests are processed via mail to support@iridi.com .

Thank you for your understanding and have a nice day.

0

Linux server start when PC starts, but cannot get to stop or restart

Hi

I have the following script that starts, stops and restarts iRidium server on Ubuntu


#!/bin/sh
### BEGIN INIT INFO
# Provides:          iridiumserver
# Required-Start:    $remote_fs $syslog
# Required-Stop:     $remote_fs $syslog
# Should-Start:      $portmap
# Should-Stop:       $portmap
# Default-Start:     2 3 4 5
# Default-Stop:      0 1 6
# Short-Description: Example initscript
# Description:       This file should be used to construct scripts to be
#                    placed in /etc/init.d.

### END INIT INFO

test -x /iridiumserver/iridium || exit 0
IRDIR=/iridiumserver
IREXE=$IRDIR/iridium
IRPID=$IRDIR/iridium.pid
IRPARAMS="--watchdog=10 --hidden"
USERID="root"

case "$1" in
start)
        echo -n "Starting iRidium server:"
        cd $IRDIR
        start-stop-daemon --start --chuid $USERID --chdir $IRDIR --make-pidfile --pidfile $IRPID    --exec $IREXE -- $IRPARAMS &
        echo "."
        ;;

stop)
        echo -n "Stopping iRidium server:"
        start-stop-daemon --stop --quiet --pidfile $IRPID
        if [ -e $IRPID ]
                then rm $IRPID
        fi
        echo "."  ;;

restart)
        echo -n "Restarting iRidium server:"
        cd $IRDIR
        start-stop-daemon --stop --quiet --pidfile $IRPID
        start-stop-daemon --start --chuid $USERID --chdir $IRDIR --make-pidfile --pidfile $IRPID    --exec $IREXE -- $IRPARAMS &  echo "."  ;;
*)
        echo "Usage: /etc/init.d/iridiumserver (start|stop|restart)"
        exit 1
        ;;

esac
exit 0


Then run the following commands in the terminal to get this to work

//move the above script to the startup folder

 cp home/linux/Downloads/iridiumserver /etc/init.d/iridiumserver

//change permissions to be executable

sudo chmod +x /etc/init.d/iridiumserver

//add the script to the startup

  sudo update-rc.d iridiumserver defaults 10

Now can run the script manually to test

  sudo /etc/init.d/iridiumserver

Result:

 Usage: /etc/init.d/iridiumserver (start|stop|restart)

 sudo /etc/init.d/iridiumserver start

Result:

  Starting iRidium server:.
   =================== Start as Daemon ===================
   Main thread exit

//enter CTL + C to get back to the terminal

  ^C

Test by rebooting

sudo shutdown -r now


The iRidium server starts.


But I cannot get the stop and restarts to work. It says cannot find the pid, and running the second time says stopping, but it does not actually stop.


Any suggestions please?


Thanks


0

Linux Server User Documents Directory Name

Jackie Roos 8 years ago in Server Solutions / Linux Server updated 8 years ago 0

Hi

On Linux, the name of the user documents "iRidium Server", with the space between iRidium and Server means to use this directory name in the command line means we must always put "" around it.


Can you please change to iRidiumServer, without the space.


Thanks


0
Answered

Обратная связь кнопок

Алекс 8 years ago in Applications / i3 Pro updated by Aleksandr Romanov (CTO) 7 years ago 2

Добрый день.

Могу -ли я получая от моего контроллера 8 битное слово по ModBus преобразовать его в 8 шт 1-но битных обратных связей для 8 кнопок. Если да то где я могу ознакомиться с подобным примером или статьей. Я не использую сервер, а на прямую отправляю данные на свой контроллер по ModBus.

0

Is your KNX driver manufacturer specific?

Laynd 8 years ago in Products / KNX 0

Will Shneider MTN6500-0113 KNX IP Router work with Iridium KNX drivers? I am new to KNX platform, need some insight.

0

FC1 Exception :1 - ERROR when using Modbus TCP Drivers on iRidium Server

TuomoHautala 8 years ago in Products / Modbus 0

I am trying to to connect to PXM PX333 DMX Controller with iRidium Server (Port 502) using Modbus TCP - driver but I am getting this error. Any idea how to fix this?

0
Answered

Как отправить IR команду через driver send ?

cyberdyne 8 years ago in Products / Other drivers updated by Aleksandr Romanov (CTO) 8 years ago 3

Заказчик купил несколько ip2ir от global cache для управлением телевизорами самсунг.

В ай3про можно загрузить команды из GC Cloud и подвесить их на кнопки.

Однако заказчик хочет создать динамичное приложение и ему требуется отправлять команды через driver send.

Получить драйвер из скрипта и выполнить send([,,,]) команды легко.

Однако как получить этот ir код который надо отправить в send ?

Например если посмотреть правой кнопкой на меню в команде ir POWER OFF то там есть такая штука как SHOW SEQUENCE - но она почему то пустая ...

Но последовательность же сохраняется в проекте и она работает - мы проверили - по кнопке все команды отлично управляют телевизором.

Как сделать управление из скрипта по команде драйвера send ?

Или как получить эту управляющую последовательность для отправки в send ?


Answer

По соглашению с GC Cloud мы шифруем хранимые команды. Поэтому получение управляющей последовательности для send не поддерживается. Не совсем понятно, что подразумевается под "динамичным приложением" и откуда появилось требование про driver send. Вы же можете из скрипта обращаться к РАЗНЫМ драйверам с разным набором команд?

0

Cannot add a states with +

Jackie Roos 8 years ago in Applications / Studio (Server editor) updated 8 years ago 0

My button has one state, now I want to add another with the +, but in 1.0.6 this is greyed out

Now I have to do this in two steps instead of one, which is really annoying

- click in the drop down

- check the box

please put the + back so it's behaviour enables the other possible states.


thanks

0
Answered

Disable orientation

Sorbodoekje 8 years ago in Applications / i3 Pro updated by Dmitry - support (expert) 8 years ago 1

I am creating an app, which will be used in portrait mode, to control lights, climate, etc. It can also show some camera pictures. I want to be able to view the camera pictures in both landscape and portrait mode. Is this possible? Without affecting the other pages. And if so, how?

0
Completed

реализация приложения просмотра 150 IP видеокамер

info 8 years ago updated by Ekaterina (head of support) 8 years ago 1

Планируем реализовать на базе iridiummobile приложение по просмотру ip видеокамер в колличестве 150 штук кто сталкивался с таким вопросом?

Answer

Это можно сделать, если одновременно показывать не более 4 (максимум 8, зависит от разрешения) видео-потоков. Других ограничений по числу камер нет.

Обратите внимание, появилась возможность настраивать камеры из скриптов, это может значительно упростить создание интерфейса:

http://dev.iridiummobile.net/Video_API#IR.CreateImage



0
Answered

Support for Domintell DINTMB01

Theo Derks - NL (distributor) 8 years ago in Products / Other drivers updated by Oksana (expert) 8 years ago 5

Hello,

Our Domintell-installers need support for the module DINTMB01.


This is a Modbus-device to control arico's (e.g. Daikin).


This module is not listed on the dev.iRidiumMobile.net as 'supported' device...


1) Why not?

2) Can you add support for this device?

3) What is the ETA for the added support?


Thanks


Theo


Answer
Oksana (expert) 8 years ago

It's added in Setup 1.0.9.431