Поделитесь своими идеями, пожеланиями и примерами в этом разделе. Идеи, за которые голосуют чаще всего, будут реализованы быстрее!
Мы перевели нашу службу поддержки на новую систему технической поддержки. С 17.01.2022 мы отключили возможность создавать обращения через личный кабинет userecho. Теперь все запросы обрабатываются по почте на support@iridi.com .
Спасибо вам за ваше понимание и хорошего дня.
KNX initial feedback request
Hi,
I was testing the App in KNX Environment (KNX UDP driver). Therefore, i was adding all necessary feedbacks from KNX, including lot of 2byte floating point values. After initialization of the app, i missed lots of them (and also others like 1bit). After investigation, it turned out that the app or the gateway does not send the requests on bus. After initial requests, i can update those values with a read request in knx, those will be updated in the app too.
Looks like that the app or gateway is running into some timeout/ or buffer overflow (if im just requesting a few feedbacks, everything works well)
MDT Gateway SCN.IP000.01 / Weinzierl BAOS 771
Ipad Air 2 / iridium v2.2
latest GUI Editor
Any suggestions?
Best,
Philipp
How to get feedback when open i2 control in control panel
Opportunity to change design (or skin) of the GUI editor
iRidium and CSV files with data
I have a question regarding the possibility of cooperating iRidium system with CSV files with data. I want to implement the following functionality: I have a PLC connected with energy meter, PLC gathers data from energy meter and saves it into CSV files. I can write a function in the PLC program which could send this CSV file into the specified localization, for example on the PC. Is it possible to send such CSV file into iRidium system and use historical logs from energy meter which are inside this file?
Best regards
Countdown Timer
Hello,
I am trying to insert a countdown timer in the application. When i press the button, the countdown starts from 60 Secs to 0 Secs.
i have tried it using the string 'GetState.Text = 60' then 'GetState.Text = 59' and so on... but i need to put delay of 1 sec in between, how is it possible?
Also, Is there any other way of doing this?
Please reply
Thanks,
Khurram
var counter; function count () { // stop interval if it has been started before IR.ClearInterval(counter); //start value var time = IR.GetItem("Page 1").GetItem("Item 1").GetState(0).Text = 60; function count () { //if time > 0 then subtract 1 and send to text field if (time > 0) { IR.GetItem("Page 1").GetItem("Item 1").GetState(0).Text = --time; } else { // stop subtracting if time <=0 IR.ClearInterval(counter); }; } // start function count every 1000 ms (1 s) counter = IR.SetInterval(1000, count); }you can start the timer with Script Call command:
C-Bus Load Completed Event
Could someone please let me know what the event I should be listening for once C-Bus has finished loading?
I want to run some script post the connection to CBus so I can display a "percentage of lights on" label.
Thanks,
Damian
If you need the event which will be activated when after the application start all feedback from C-Bus is received, then we don't have such event.
If you need the event of when the driver connected to the equipment (EVENT_ONLINE), then it doesn't work for the C-Bus driver.
We can recommend you to set up delay after the application start and then monitor the Online token (see the project in the attachment). The delay has to be selected individually for your installation after checking in the log when the last feedback from the equipment comes.
C-Bus SetInterval Status.irpz
Sincerely yours,
Olga Ermakova
iRidium mobile Team
Have you heard or work with an alarm system controlled by iridiummobile?
How can we observe open level of shutter and sliding gate?
I used iridium to control MyHome system . Please help me !
Меню, открываемое жестом
Чтобы использовать меню в своем интерфейсе, перетащите этот пример в свой проект (тащим проект за имя), и редактируйте скрипт в соответствии с комментариями.
Сервис поддержки клиентов работает на платформе UserEcho