Add your idea or search for answers in existing topics. The most popular ideas will be implemented faster!

We have moved our support service to a new technical support system. Since 17.01.2022, we have disabled the ability to create appeals through the userecho personal account. Now all requests are processed via mail to support@iridi.com .

Thank you for your understanding and have a nice day.

0
Answered

Lisans

Yeliz Tarhan 9 years ago in Products / AV & Custom Systems updated by Dmitry - support (expert) 9 years ago 2

Hi


Image 9870


If we add İridium base in Global cache which license? (Pro shold?)


Thanks

0
Answered

Iridium + KNX

Егор Мазуров 8 years ago in Products / KNX updated by Oksana (expert) 8 years ago 1

Здравствуйте. При подключении к KNX IP роутеру в эмуляторе Iridium выдает ошибку: Time of waiting for connection is over. Что это может быть и как это исправить? Спасибо.

Answer
Oksana (expert) 8 years ago

Здравствуйте, Егор


Вам уже было отвечено в предыдущей созданной теме: http://support.iridiummobile.net/topic/1067156-iridium-knx/


Так как вы пишите на русском языке, ваш вопрос был перенесен в форум для русскоязычных пользователей.

0
Answered

SIP management and Sleep Product

Patrick PETIT 9 years ago in Products / Other drivers updated 9 years ago 9
Hello,

First of all, sorry I do not speak English and I hope my question is clear enough.

I do not know the SIP protocol, so I appreciated being able to use the iRidium Mobile SIP client (javascript module).
I made some tests with 3 x SIP clients:
- 1 SIP client (SIP Javascript iRidium Mobile module) installed on a desktop PC (with windows 7)
- 1 SIP client (SIP Javascript iRidium Mobile module) installed on a laptop PC (Windows 8.1)
- 1 SIP client (SIP Javascript iRidium Mobile module) installed on a tablet (android 4.1.1)


The 3CX SIP server is installed on the laptop PC (Windows 8.1).

For the tests I have not audio/video door. I did the tests with only the 3 clients iridium described above.
I configured the 3 clients and 3CX Phone System in accordance with the Note: http://wiki2.iridiummobile.net/Setting_up_SIP_Telephony_in_iRidium#Setting_up_SIP_Servers
 
The calls made by each client are working. But after a time, one or more clients no longer appear on the server (telephone) and are no longer managed.
 
I removed 
the sleep of the laptop PC on which the server is installed and this seems to be the solution to the problem.
Next, I programmed on the android tablet where a SIP client is installed, a sleep after a few minutes. And exactly the same problem.
 
You cannot program a sleep on the tablet or on the PC with SIP management ?

Best Regards,

Patrick
Answer
Olga (expert) 9 years ago
Dear Patrick,

I just noticed that without any action, the number 11 SIP client had been deleted from the server and then added again 1-2 minutes later.

We know about that and change the registration procedure in V2.2.2 a little. But there is no setup for Android at the moment, for Windows and iOS only.

Please see the version for Windows for your testing:
1. Copy the current versions of the files iRidium.exe and Squall.dll from the folder C:\Program Files (x86)\iRidium mobile2\iRidium and save them separately. 
2. Substitute the files in the folder with the licenses from the attachment.
3. Test.

As for the issue, that you cannot find the client on the server, we hope that the changes will fix it.

Sincerely yours,

Olga Ermakova
iRidium mobile Team
iRidium (2).zip

0
Under review

Iridium Editor having problem with the HDL bus pro 8 in 1 sensor module latest

Punith 9 years ago in Products / HDL-BUS Pro updated by Ekaterina (head of support) 9 years ago 11
In iridium Editor I have configured TV for Universal switch ,, Some of Rooms Switch not working with the 8 in 1 sensor ,,When i try it manually with the sensor ,it works fine ,, when i am trying to work with the iridum Ipad, It does not work here all 8 in 1 sensor configured IR signals are same,, Here i came to know two models sensor are used for the TV configuaration in that one 8 in 1 sensor model(HDL.MS08M.2C) and second 8 in 1 sensor model (HDL.MS08Mn.2C) ,, Those models have Same IR signal Functions ,, here (HDL.MS08M.2C) model is working fine with the iridium ipad applicatio,,,, (HDL.MS08M.2C) model doesnt work with the iridium IPAD,, BUt Its working by manually as i checked in transmit signal,, It works,, when I try to check it on the iridum application ,, it doesnot work,, ,,
0
Answered

​A panel (a device license) ​ can control a project all devices?

losihg2009 l 9 years ago in Products / HDL-BUS Pro updated by Dmitry - support (expert) 8 years ago 6
A panel (a device license) can control a project all devices? The project has two or more IP module (HDL-MBUS01IP.431).How to setup?
Answer
IF all the IP modules (HDL-MBUS01IP.431) is in the same network, you don't need an additional settings.
Use the Host 255.255.255.255 in iRidium and you will be able to control all the devices

0
Not a bug

iRidium native KNX driver (KNXnet/IP) doesn't work with ABB IPR/S 2.1 in Routing mode (nat=false)

Эмиль Боев 9 years ago in Products / KNX updated by Ekaterina (head of support) 9 years ago 3
See the title of topic, please.
In tunneling mode (nat=true) it works fine.

Also, from the same pc laptop (through the same LAN/WAN equipments) another KNXnet/IP client works just fine in routing mode.

Suggestion: the problem in so called ActionMessageCode.
Some KNX Routers/Interfaces might need this parameter defined, some need this to be 0x29.
ActionMessageCode is the first byte after header in KNXnet/IP packet.
For example, for Action packet header if [0..5] 6 bytes length. And the seventh [6] byte will be exactly the ActionMessageCode.

If ActionMessageCode is not 0x29, it will be always equal to 0x11.



0
Answered

Getting a text string from modbus wago to Iridium 2.0

D-man 11 years ago in Products / Modbus updated by Oksana (expert) 9 years ago 8
Hello,

is it possible to pick a string of text out of a modbus device [wago 750-881 controller] to Iridium.

I can view the string in Iridium but Iridium makes a number of it, and not the line of text i typed in the modbus device.

I hope someone can tell me if this is possible and how to do it.
0
Answered

Dynamic change network connection settings for AMX Controller

Рустем Зиятдинов 9 years ago in Products / AMX updated 9 years ago 2
Hello,
Is it possible to change network connection settings for AMX Controller using JS?
I need to set AMX Controller IP address based on information in the external database.

Answer
Olga (expert) 9 years ago
Dear Rustem,

The settings of connection to AMX are available for writing via scripts with the following construction:
IR.AddListener(IR.EVENT_START,0,function() 
{ 
    IR.GetDevice("AMX").SetParameters({ Host: "192.168.0.21", 
                                        Port: "12004", 
                                        DeviceID: "1", 
                                        Login: "admin", 
                                        Password: "12345"}); }); 
http://wiki2.iridiummobile.net/Drivers_API#SetParameters

The SetParameters function can activated not at start but after receiving data from the database. The host and port fields should be left empty in the driver settings so that initially the project wouldn't connect to any controller. The , конечно, можно вызвать не по старту, а после получения данных из базы.
The parameter HostIP from the driver tokens is not aailable for writing. The SetParameters function sets all connection parameters at once and you cannot change any of them, if you don't have a password. You need to indicate
Password: ""
There is an instruction for setting up connection parameters in the description of the АМХ driver. Besides commands from iRidium Script API you can use the AMX command Loopback Port. The principles of its work ans setting is not different from the ones for IR.SetParameters

Sincerely yours,

Olga Ermakova
iRidium mobile Team
0
Completed

HDL ethernet 1-port в качестве шлюза между ethernet и rs485

Дмитрий Марков 8 years ago in Products / Other drivers updated by Ekaterina (head of support) 8 years ago 1

Добрый день!

Можно ли использовать любое HDL-устройство, имеющее на борту ethernet-порт, как шлюз для отправки команд по протоколу rs485 через ethernet, через драйвер AV&Custom systems? Т.е. отправляем команды rs485 на порт 6000 шлюза, он транслирует эти команды оборудованию (не HDL), подключенных к порту 485. Если такой вариант возможен, какие параметры скорости и т.д. HDL-шлюз поддерживает?

0
Completed

Nuvo Control

James R Delaney 8 years ago in Products / Other drivers updated by Andrey S 7 years ago 2
Requests for Drivers