Problem with feedback from multizone tcp controller
I have a problem to get a feedbeck from my multiroom controller.
i can control system when sending commands like this one:
'#|X001|web|SVD01|0|U|',13,10
But i can't get any feedback from controller and the only commandes i have from manufaktur is:
Example Get routing info for zone 1 Command
#|X001|web| GV01|0|U|return
Answer #|web|X001| V01|20|U|return
I have tried to read feedback into a value or text field but without succes.
i hope somebody can halp.. thx
Камеры панелей управления в Iridium
Столкнулись с задачей реализации видеоинтеркома. Имеется частный дом, несколько этажей, пользователь хочет помимо аудио-интеркома, еще картинку. Так же это может быть использовано, например, для удаленного просмотра происходящего в области видимости камеры, особенно если панель установлена на постоянное место, это позволит частично заменить бросающуюся в глаза ip-камеру. Видеоняню можно записать сюда же.
Number of KNX group addresses with i2control V2.2
Are there a limitation on the number of KNX group addresses with i2control V2.2. I use the Weinzierl BAOS 772 interface that can handle 1000 address groups
Patrick
Dry HDL Status in BackGround
I want to make a simple warning system of technical alarms. For this I use a dry contact module of HDL.
The system works correctly, when I'm inside it, but when I´m running in the background is not working. What can be wrong?
Attach the project to be better understood.
Note: To make the system work I had to use the "Security Dry Contact Read Status" option and also had to make ask the state of this variable at some time period, otherwise not give me the information about the state of the dry contact.
In the AMX driver does not work the command ^RMF
Adjusting temperature in Domintell
Reading the temperature is no problem but I can not find how to adjust the temperature in a specific room. Everything is controled by Domintell.
Project coolmaster 1000D
Modbus protocol in Background execution mode
Am I doing something wrong?
At the moment notifications for the background mode (minimized or closed application) are not supported. http://wiki2.iridiummobile.net/Working_with_Equipment#Notifications_about_System_Events
Function "Don't sleep" doesn't let your device sleep if the app is active (it isn't minimized or closed)
Sincerely yours,
Oksana Storozheva
iRidium mobile Team
TCP TO UDP GAte
iRidium has a special command which changes the external address to the internal one:
http://wiki2.iridiummobile.net/Basic_Operation_of_iRidium_with_Modbus_Controllers#Switching_Between_the_Local_and_Internet_Connection
You need to use it for switching between the local network and the Internet.
If the connection doesn't work when working in the local network, it means that the router blocks the connection. It is standard for many routers. You can change the router or use the ready tool for switching networks.
Sincerely yours,
Olga Ermakova
iRidium mobile Team
Recive Feedback from lighting in My Home System - Bticino
Hello everybody.
I use iRidium to control MyHome system.
I have done project with iRidium when i control lighting with A=1-9 PL=1-9 it control and feedback success. But with A=1-9 PL=10-15 it can control but it do not feedback ?
I want to ask how to get feedback with PL>=10; thanks