Напишите здесь описание Вашего форума ...
0

Memory expansion UMC

Alessandro Munari 5 months ago in Ideas • updated by Vladimir Ovchinnikov 4 months ago 1

Continuing the previous topic of Memory expansion on UMS server ....

I know that when I select from the studio which variable to store it goes directly in the Iridium database. How can I choose in wich database to store the variable ?

I need to create script for that ? 

I think it will be good to add the popssibility to choose in wich directory to store the db file, and also allow, from the web server interface to select an USB or NETWORK path ... 

Don't you think is a good idea. The memory of UMC is very limited, but it can be expanded with USB drive or NETwork path (FTP, i.e) ...

0
Will be answered

IFTTT Integration with iRidium Server

Alessandro Munari 5 months ago in Ideas • updated by Aleksandr Romanov (CTO) 2 months ago 13

Are you planning also to provide a Service in IFTTT to be able to send/receive commands with the help of IFTT service ?

as example, when the phone enter in a specific area, I can send command to iRidium Server (meybe open the garage door, etc,turn on the external lights, ...)

0
Completed

UMC memory expansion for database file

Alessandro Munari 7 months ago in Ideas • updated by Vladimir Ovchinnikov 1 month ago 10

Hi, I noticed that the UMC server has a USB port. Is there any possibily to use this port to store the Server database ?

Maybe it requires some changes on server to select in wich path to store the database file.

If I use a 30Gb USB memory drive, I can store very large ammount of data into the UMC server.

Is there any possibilities ?

0

Using Philips Hue Dimmer Switch to send commands in a project

Iain Brew 7 months ago in Ideas 0

I am curious if anyone has successfully implemented the following. I have a Philips Hue bridge and a Philips Dimmer Switch. This switch has four buttons on it which send commands to the bridge to then trigger lighting presets etc. The Hue system has an open API which allows you to query what button has been pressed on the dimmer switch. 

Effectively, instead of having the dimmer switch buttons controlling a light, I want to read its status (feedback) and have it send a command to a driver instead. For example:

Press Dimmer Switch 1 = send command 'x' to driver 'y'

Press Dimmer Switch 2 = send command 'a' to driver 'b' and send number '8' to token 'z'

and so on...

If anyone has any examples of this working or could advise a cleaner solution for inexpensive wall mountable buttons to trigger feedbacks I would be very appreciative!

0
Answered

Copy of iridium lite project

enw.matt 9 months ago in Ideas • updated by Aleksandr Romanov (CTO) 9 months ago 1

Hi we have many similar projects and created a templat iridium lite project with licence.

We would like to use this project as a template for new projects to minimise work, the copy would automatically be a trial version which would then require the purchase of a license.

Can this be done?

0
Answered

Import a website to iridium application

Mantas Jasiulis 10 months ago in Ideas • updated by Aleksandr Romanov (CTO) 8 months ago 6

Hello,

I want to import a scheduler from my logicmachine to iridium app so that the end user can modify the time intervals. Is it possible to access website from iridium? I have a direct link to the scheduler so I just need to somehow open it from iridium.

0
Completed

specific data stored/saved into in each client application

Christophe MATHEY 10 months ago in Ideas • updated by Vladimir Ovchinnikov 10 months ago 6

for example, specific parameters for each panel/user and saved by each panel/user.



0

Bacnet in Iridium Lite

David Lagos 11 months ago in Ideas • updated by Vladimir Ovchinnikov 10 months ago 1

Dear Iridium Support Team


I think that Iridium Lite is a good product, its configuration is faster and simpler than configuration of Iridium Pro. However, Iridium Lite does not have a Bacnet module.


If you will add a Bacnet module in Irdium Lite then integration with Bacnet Systems will be easy.


Do you plan to develop Bacnet module for Iridium Lite?

0
Declined

Control4 Compatibility

Matteo Manica 1 year ago in Ideas • updated by Aleksandr Romanov (CTO) 1 year ago 1

Hi, in the future there is a plan for make iRidium compatible with Control4 system?

Kind Regards

0
Under review

Volume level - Serial rs-232

Christine Bizarello 1 year ago in Ideas • updated by Vladimir Ovchinnikov 1 year ago 3

I have a project for AV automation and I'm using a global cache driver to control the device trough rs-232 port.

My device has the command "<11VOxx0x0D" to control the volume, where the 'xx' is the level of volume that goes from 00 to 38.

I need to create a level that controls this volume without the need of the creation  of 38 buttons for it. Can anyone help me?