We have moved our support service to a new technical support system. Since 17.01.2022, we have disabled the ability to create appeals through the userecho personal account. Now all requests are processed via mail to support@iridi.com .

Thank you for your understanding and have a nice day.

0
Beantwoord

iridium lite multiple panels

Roxana Vremi 4 jaar geleden bijgewerkt 4 jaar geleden 8

It is possible to have multiple control pannels when using Iridium lite?

0
Beantwoord

iRidium Server virtualization

Leandro Augusto 4 jaar geleden bijgewerkt 4 jaar geleden 4

Does iRidium Server have support for virtual servers?  

0
Beantwoord

Отображение статуса

Денис Коваленко 4 jaar geleden bijgewerkt door Tatiana Kiselyova (expert) 4 jaar geleden 3

Здравствуйте, хотелось бы узнать, есть ли какой то элемент графический или нечто подобное, что сможет отобразить статус работы приходящий в виде числа от 0 до 3? допустим 0 соответствует отключению, а 1-2-3 степеням мощности

0
Beantwoord

IP Telephone & intercom interface with iridium Pro

Ahmed-eg 4 jaar geleden bijgewerkt door Aleksandr Romanov (CTO) 4 jaar geleden 1

Hello,

I am planing to install KNX, IP PBX  along with face video intercom that supports RTSP protocol, and was wondering if i will need any additional hardware to interface it with Iridium Pro and if there is any guidelines i would appreciate it.

Thanks in advance,

Ahmed

0
Beantwoord

Android Studio Inent

Richard t Lam 4 jaar geleden in Tips and Tricks bijgewerkt door Vladimir Ovchinnikov (expert) 4 jaar geleden 7

Hello,

I am building or own application on android.

I want to start i3 Pro application from my application.

I need the intent from the app. For startin the activity.

For example this is the intent for starting the settings application: android.procider.Settings.ACTION_Settings.

startActivityForResult(new Intent(android.provider.Settings.ACTION_SETTINGS), 0)
0
Beantwoord

Force read a KNX address bypassing the iridium tag

Dan 4 jaar geleden in Tips and Tricks bijgewerkt door Aleksandr Romanov (CTO) 4 jaar geleden 2

Hi,


We have a server project with a KNX IP Router driver present that occasionally fails to receive an update from the KNX bus when bus activity is high.

By monitoring the KNX bus I can see that both the command and feedback is sent across the KNX bus, but the feedback simply doesn't make it to the iRidium server driver. This causes an issue in that the tags storing these levels will be incorrect until the knx address makes another change.

To retrieve the value of a specific KNX address I am indexing

`var value = IR.GetVariable("Drivers.KNX Server.KNX IP Router.1/6/250");`

which retrieves the old value.

My question is this - is there a way I can force a re-read of a specific KNX address? So that if I detect that no update has been received when it should, I can force the KNX IP Router driver to actively read the KNX bus, instead of relying on its cached value?

Looking forward to your reply,

Dan


0
Under review

i3 Pro crashed with SIP

anaximandre 4 jaar geleden in Bugs and problems bijgewerkt door Arina Kiselyova 4 jaar geleden 2
0
Under review

slideshow screensaver

S CL 4 jaar geleden in Ideas bijgewerkt door Arina Kiselyova 4 jaar geleden 1

Hi,


Is there a possibility that the screensaver function shows more than 1 page/ picture?
To the idea of a slide show.

0
Beantwoord

[iRidiumServer][Linux] How to backup and restore database

Francesco Zangara 4 jaar geleden bijgewerkt door Vladimir Ovchinnikov (expert) 4 jaar geleden 7

Good day,

i have an iRidium Server on RaspberryPi with SD damaged, so i need to move the project and database to a NUC with Raspberry Pi OS for Desktop.

I install iRidiumServer for Linux and upload my project from cloud. More i move the IridiumStorage.db from "/var/lib/iRidium Server/Database" on RaspberryPi (old backup) to "/root/iRidium Server/Database" on NUC.

After, i run iRidiumServer and it work correctly and i see the correct size of DB on webpage, but i can't see the data on variable chart.

How can i check if iRidium load correctly the DB? And load old data storaged in DB?

0
Under review

feedback and invert feedback

jos 4 jaar geleden in Bugs and problems bijgewerkt door Vladimir Ovchinnikov (expert) 4 jaar geleden 1

I have a project with a trigger button which triggers an KNX relay which is assigned normally closed. so if i send 1 the feedback will be 0 and vica versa. This gives a problem with the trigger button because it gets feedback 0 and so wants to send 1 but the relay already got 1 so does nothing and by another press it will send 0 and then the relay will change and gives feedback 1 and so on. I thought when if change feedback from channel to invert channel this would solve the problem, but this doesn't change anything. How do i solve this and what is the difference between feedback channel and invert channel ?