Not a bug

Deadband not working for float-numbers

Martin Lang 8 jaar geleden in Server Solutions bijgewerkt door Oksana (expert) 8 jaar geleden 5

i tried to setup the deadband for floatnumbers (temperaturs) to 0,2 or 0,5. but this isn't working.

the character point "." is not accepted in the input field. when using 0,2 for example, the server still stores integer jumps.

Antwoord
Oksana (expert) 8 jaar geleden

Hello Martin,

Can you send us your project? We can't repeat.


This is example with Virtual Server Command and Tags.

Float deadband.sirpz

You should set values via Web-interface to Command "Virtual 1" (you should set via point, for example, "1.1"). Web-interface sends value as strings, and function "parseFloat()" changes this string to float


If we test deadband via Modbus TCP driver (for example), we don't need to use "parseFloat()"



+1
Under review

Function to validate against passwords set in Transfer

Wouter van der Post 8 jaar geleden in Applications / i3 Pro bijgewerkt door anonymous 8 jaar geleden 1

In Transfer it is possible to set 4 passwords that you can use for a button functionality to become 'password protected'.

However I would like to design my own password screen/popup and would like to be able to validate the entered password against one of those 4 passwords. Is there a way to "get" one of those passwords in JS? Or validate a string against them?

Something like:

if(IR.ValidatePassword([password string], 1, 2007) {
}

The "1" parameter indicates which of the 4 passwords should be used, could be an enum too.

The "2007" parameter is a default value to use in the emulator, since you cannot set one of the passwords there.

+1

Unused objects in Alphabetical order

Jackie Roos 8 jaar geleden in Applications / i3 Pro 0

Image 16771


Please change to have alphabetical order


Quite often there are dynamic images that are used when changing from LAN to phone network and it can be difficult to find and un-select them


thanks

+1
Beantwoord

What EVENT will be triggered when updating the i3 server?

Martin Lang 8 jaar geleden in Server Solutions bijgewerkt door Aleksandr Romanov (CTO) 8 jaar geleden 6

Hi,


is there an event that would be triggered right before a new project

will be uploaded to the server to have time to save some data in the database?


Ciao

Martin

+1
Beantwoord

PLease include the lastest HDL Wireless devices in iRidium 3.x

Martin Lang 8 jaar geleden in Products / HDL-BUS Pro bijgewerkt 8 jaar geleden 8

hi,


please include the latest HDL wireless components correctly

into iRidium 3.x


for example there are new "1channel relais", "2channel relais", "1channel curtain control" out

with changed id-codes depending on a new firmware in these modules. iRidium doesn't recognize

them correctly.


also, all these new HDL wireless devices have 4-dry-contact inputs.these should be also included

directly into each device. otherwise we allways have to write additional devices and give them the same subnetid/deviceid, thats bad.


also the outdoor microwave/lux/humidity/temperature sensor is not recognized corrects, along with the wireless dlp panels! they have inbuild dimmer support.


and last big question, is it possible to clone/copy a self created hdl-device after setting it up with all the commands and feedback-channels needed? i can't see this option in the list?


thx!


martin lang

+1
Beantwoord

Размер окна Свойства

Evgenii 8 jaar geleden in Applications / Studio (Server editor) bijgewerkt 8 jaar geleden 3

Почему окно Свойства не может быть изменено по размерам?

+1
Under review

Отображение в панели задач

AlexDr 8 jaar geleden in Applications / Studio (Server editor) bijgewerkt door Oksana (expert) 8 jaar geleden 0

Во время загрузки проекта иридум, в котором есть ссылка на серверный проект, редактор спрашивает "Загрузить серверный проект?". Проблема в том что это диалоговое окно не отображается в панели задач и после запуска файла проекта (загрузка которого занимает некоторое время) оно оказывается за другими окнами.


Если бы в панели задач отображался иридиум во время загрузки - было б гораздо удобнее.

Image 16371

+1

Хотелось бы иметь EditBox для ввода многострочного текста

a pivovarov 8 jaar geleden in General bijgewerkt door Dmitry - support (expert) 8 jaar geleden 1

У меня есть такое окно, в котором вводится текст.

Текст длинный и не помещается в окно.

Хотелось бы иметь полноценный editbox со скроллбарами и т.д.

+1
Voting

Получение статусов ошибок

a pivovarov 8 jaar geleden bijgewerkt door Aleksandr Romanov (CTO) 8 jaar geleden 3

Хотелось бы иметь возможность получать статусы ошибок подключения к серверу и драйверам.

+1
Beantwoord

2n helios ip

Khurram Masud 8 jaar geleden in Products / Other drivers bijgewerkt door Aleksandr Romanov (CTO) 7 jaar geleden 2

Hi,

I am interested in adding 2N Helios ip door intercom to my project. I have no idea where to start, anybody can help me with that. I have tried using SIP intercom but that is not working for me. Any suggestions please,


Thanks